Accurate, Color-independent Measurement

Primary and active sludge with different structures and colors, dark digested sludge and light lime sludge make the highest demands on the precise measurement of solids. Only SOLITAX sc solids probes with the patented dual scattered light method can satisfy these demands.

Self-cleaning Wiper Prevents Erroneous Values

The SOLITAX sc sensor's self-cleaning wiper prevents erroneous values and maintenance problems by preventing biological growth. Gas bubbles in the sample do not interfere with the measurement.

Easy One-point Calibration

All SOLITAX sc probes are factory calibrated in conformity with DIN EN ISO 7027 for long-term calibration stability. Calibration is not necessary. If the probe is used to measure the solids content, a one-point calibration suffices. Multipoint calibration is available for nonlinear samples.

Improve overall efficiency of the plant

Any two SOLITAX sc sensors can be installed using one HACH sc200 Controller. Helps improve process control and reduce treatment costs associated with polymer use, digester volume, and sludge handling.

What's included?

Turbidity & Suspended Solids probe, controller, user manual

Specifications

Accuracy: Turbidity up to 1000 NTU:
without calibration < 5% of the measured value ±0.01 NTU
with calibration < 1% of the measured value ±0.01 NTU
Automatic Wiper: Yes
Body Material: Stainless Steel
Cable Length: 10 m (optional extension cables available)
Calibration Method: Turbidity: Formazin or STABLCAL Standard (at 800 NTU).
Suspended Solids: Sample specific, based on gravimetric TSS analysis with a correction factor procedure.
Certifications: CE
Configurations: Includes SC200 Controller
Controller: SC200
Diameter Sensor: 60 mm
Flow: Max. 3 m/s (the presence of air bubbles affects the measurement)
Includes: Turbidity & Suspended Solids probe, controller, user manual
Installation style: Tank Immersion
Length: 200 mm
Maintenance Interval: 1 h/month
Material: Optics Carrier and Sleeve: stainless steel 1.4571; Wiper Arm: stainless steel 1.4581; Wiper Rubber: silicone rubber (standard) Optional: FKM/FPM (LZX578); Wiper Shaft: stainless steel 1.4571
Max. cable length Sensor-to-Controller: 100 m
Measuring Principle: Infrared Duo scattered light technique for color-independent turbidity measurement. Turbidity in accordance with DIN EN ISO 7027 / TS equivalent DIN 38414
Model: Solitax hs-line sc
Mounting: Immersion
Operating Temperature Range: 0 - 40 °C
Parameter: Suspended Solids, Turbidity
Pressure Range: Stainless steel immersion sensor: <6 bar or <60 m
Range: TSS-content: 0.001 mg/L- 500 g/L
Turbidity: 0.001 - 4000 NTU
Repeatability: TSS content: < 3 %
Turbidity: < 1 %
Response Time T90: 1 - 300 s adjustable
Warranty: 12 months
Weight: 1.38 kg
What's included?: Turbidity & Suspended Solids probe, controller, user manual