CLT10sc Total Chlorine Analyzer with sc200 Controller and Combination pH Sensor (Metric)

OBSOLETE ITEM

CLT10sc Total Chlorine Analyzer with sc200 Controller and Combination pH Sensor (Metric)
Product #: 2983100

OBSOLETE ITEM

Compatible with Hach's "Plug and Play" Digital Controllers

The CLF10 sc and CLT10 sc Chlorine Analyzers are designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.

No Reagent Replacement, No Waste Stream

Chlorine measurement with the CLF10sc and CLT10sc amperometric technology eliminates the need for routine reagent replacement and waste stream management.

EPA Compliance

The CLF10 sc and CLT10 sc analyzers can be used for reporting chlorine residual measurements in accordance with EPA Method 334.0. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required for Method 334.0.

Advanced Diagnostics

CLF10sc and CLT10sc advanced diagnostics alert you when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow.

Real-time Process Monitoring and Control

The CLF10sc and CLT10sc Chlorine Analyzers allow for real-time monitoring and control of disinfection processes.

What's included?

Hach sc200 Controller, Mounting Hardware, sc200 Basic User Manual, CL10sc Panel, 1 M digital extension cable, Panel Manual, Combination pH Sensor Manual, Chlorine Sensor Manual.

Specifications

Accuracy: Free Chlorine: ±3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit)
Accuracy 2: Free Chlorine: ±10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
Accuracy 3: Total Chlorine: ±10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
Accuracy 4: Total Chlorine: ±20 % of the reference test** (DPD) at stable pH greater than 8.5
Cable Connection: 5 pin, M12 connector
Cable Length: 1 m (between gateway and sc controller)
Calibration Method: (zero and slope) calibration
Calibration Method 2: (zero and slope) calibration
Certifications: CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Additional certifications when connected to an sc controller
Connection Drain Line: pH Flow Cell Outlet: 1/2-inch ID
Connections: 1/4 inch OD
Controller Compatibility: sc controller platform
Dimensions : mm x 25 mm (7.68 in x 0.98 in)
  Sensor Only: 195
Interferences: Monochloramine, chlorine dioxide, ozone,
and chalk deposits
Length: Sensor: 195 mm
Lower Limit of Detection (LOD): 30 ppb (0.03 ppm)
Material: Corrosion-resistant materials, fully-submersible
(stainless steel, PEEK, PVC, silicon rubber and polycarbonate)
Measurement method: Reagentless, electrochemical, three-electrode amperometric system
Mounting: Panel or Wall Mounting
Operating Temperature Range: 0 - 45 °C
pH Range: 4 - 9
Power requirements (Voltage): 12 V DC
Pressure Range: 0.5 bar, no pressure impulses and/or vibrations
Range: 0 - 20 ppm Cl₂
Response Time: Free Chlorine: 140 s or less for 90% change (T90)
at a stable temperature and pH
  Total Chlorine:100 sor less for 90% change (T90)
at a stable temperature and pH
Sample Flow Rate: 30 - 50 L/h (7.9 - 13.2 gal/hour), Optimal is 40 L/hour (10.5 gal/hour)
Sample Temperature: 5 - 45°C(41 - 113°F)
Ship Wt. (lbs): 9.1
Warranty: 1 Year
Weight: 5.5 kg Approximately 5.5 kg (12 lbs)
Panel and empty panel-mounted components only
What's included?: Hach sc200 Controller, Mounting Hardware, sc200 Basic User Manual, CL10sc Panel, 1 M digital extension cable, Panel Manual, Combination pH Sensor Manual, Chlorine Sensor Manual.