2100N Laboratory Turbidimeter, EPA, 115 Vac

OBSOLETE ITEM

2100N Laboratory Turbidimeter, EPA, 115 Vac
Product #: 4700000

OBSOLETE ITEM

What's included?

Instrument, sample cells, Stablcal calibration standards in sealed vials, silicone oil, oiling cloth, dust cover, manual, power cord with North American plug, EPA filter assembly.

Specifications

Accuracy: ± 2 % of reading plus 0.01 NTU from 0 - 1000 NTU
±5% of reading from 1000 - 4000 NTU
Air purge: 0.1 scfm at 69 kPa , hose barb connection for 1/8 in tubing, maximum 138 kPa. Dry nitrogen or instrument-grade air.
Compliance Certifications: UL/CSA
Dimensions (H x W x D): 156 mm x 400 mm x 305 mm
Display Type: 8-digit LED display
Interface: RS232 serial (bi-directional)
Lamp Type: Tungsten
Manual Languages: English, Spanish, French, German
Max. operating humidity: 90 %
Measurement Modes: NTU, EBC, Nephelo
Operating Temperature Range: 0 - 40 °C
Power Options: 115 V AC with US power cord
Power Requirements: 115 - 230 VAC; 50 to 60 Hz; 60 VA maximum
Range: 0 - 4000 NTU
  0 to 0.999 EBC units EBC mode, ratio on: manual
  0 to 26800 Nephelos Nephelo mode, ratio on: auto, auto-decimal
  0 to 26800 Nephelos Nephelo mode, ratio on: manual
  0 to 268 Nephelos Nephelo mode, ratio off
  0 to 40.0 NTU NTU mode, ratio off
  0 to 4000 FNU
  0 to 4000 NTU NTU mode, ratio on: auto, auto decimal
  0 to 4000 NTU NTU mode, ratio on: manual
  0 to 9.8 EBC units EBC mode, ratio off
  0 to 9.99 EBC units EBC mode, ratio on: manual
  0 to 9.99 Nephelos Nephelo mode, ratio on: manual
  0 to 9.99 NTU NTU mode, ratio on: manual
  0 to 980 EBC units EBC mode, ratio on: auto, auto-decimal
  0 to 980 EBC units EBC mode, ratio on: manual
  0 to 99.9 EBC units EBC mode, ratio on: manual
  0 to 99.9 Nephelos Nephelo mode, ratio on: manual
  0 to 99.9 NTU NTU mode, ratio on: manual
  Ratio On: Manual 0 - 10000 ; Auto 0 - 10,000 auto decimal; Ratio Off: 0 - 40.0
Regulatory: USEPA method 180.1
Repeatability: ± 1 % of reading or ± 0.01 NTU, whichever is greater
Response Time: 6.8 s with signal averaging off; 14 s with signal averaging on
Sample Cell Compatibility: 25 mm round; 12, 13, 16, and 19 mm round with optional adapter kit
Sample Volume: 30 mL with 25 mm sample cells
Serial input interface: RS232 serial interface (bidirectional)
Source Lamp: Tungsten lamp
Stabilisation time: 30 min with ratio on
Stabilization time: 60 min with ratio off
Storage conditions: -40 °C to 60 °C
User Interface: Button
User Interface Languages: English
Weight: 3.43 kg
What's included?: Instrument, sample cells, Stablcal calibration standards in sealed vials, silicone oil, oiling cloth, dust cover, manual, power cord with North American plug, EPA filter assembly.