AS950 Refrigerated Sampler Bundle, 230V, with 1 - 2.5 Gallon Bottle and sensor ports.

OBSOLETE ITEM

AS950 Refrigerated Sampler Bundle, 230V, with 1 - 2.5 Gallon Bottle and sensor ports.
Product #: ASR.CSXX2X21XX

OBSOLETE ITEM

Easiest and Most Intuitive Operation

The large full color display and intuitive programming give you access to all your programmable criteria on a single screen - eliminating scrolling through menus and supporting error-free operation.

Most Convenient Data Transfer and Programming Available

The AS950 is the only sampler that utilizes a USB drive to upload and download data and copy programs from one sampler to another.

Confidence in Your Sampling Process

The program status screen instantly communicates alarms, missed samples and program progress for quick and easy troubleshooting.

Resists Corrosion

The refrigerated sampler base is designed to endure humid and highly corrosive environments, minimizing damage caused by corrosive gases, rodents, and standing water to guarantee environmental integrity.

Accurate and Consistent Sample Preservations

The custom-designed air-sensing thermostat controls temperature in accordance with USEPA and international guidelines, preserving samples regardless of outside temperatures and conditions.

What's included?

1 ea. AS950 controller with sensor ports on vinyl 230V refrigerated base
1 ea. Bottle kit (RF010030) includes 2.5 gallon polyethylene bottle w/cap (1918), extension tube (3527), composite tube support (8986) and full bottle shut-off (8847)
1 ea. 25' vinyl intake tubing (920)
1 ea. strainer (926)

Specifications

Alarm: Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
Automatic Shutdown: Multiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected)
Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container.
Base Type: Vinyl
Body material: 22 Gauge Steel (optional Stainless Steel) with vinyl laminate over-coating (Sampler)
Bottle Set: Composite (1) 2.5 gallon polyethylene bottle kit
Certifications: CE, UL
Communication Capabilities: USB and optional RS485 (Modbus)
Cooling system: 1/7 HP, 75 Watt, 400 BTU/hr compressor, 120 CFM condenser fan, three-sided wraparound plate type evaporator, rigid foam insulation, air sensing thermostat capable of maintaining sample liquid at 4°C (39°F) in ambient temperature to 49°C (120°F) maximum; accurate to ±0.8°C (1.5°F), magnetic door seal
Data logging: SAMPLE HISTORY - Stores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery).

MEASUREMENTS - Stores up to 325,000 entries for selected measurement channels in accordance with the selected logging interval.

EVENTS - Ability to store up to 2000 entries in Sample History logging. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected.
Diagnostics: View event and alarm logs as well as maintenance diagnostics
Dimensions :
Please contact your Hach sales representative for details.
  61 x 61 x 112 cm (24 x 24 x 44 in.)
  NON-CONTACT LIQUID DETECT
Sample volume accuracy for applications that require complete tubing replacement
  RAIN/RS485 PORT
Accepts Hach Rain Gauge (not included) or can be used as RS485 communications
  TWO SENSOR PORTS
Accepts Hach digital Differential pH, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors
Display: 1/4 VGA, Color; self-prompting/menu-driven program
Display Lock Function: Access code protection prevents tampering
Housing Material: PC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller)
Inputs: One 0/4-20 mA input for flow pacing
Intake: Strainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications

Purge: Air purged automatically before and after each sample;
duration automatically compensates for varying intake line lengths

Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses

Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
Internal Clock: ±1 second per day at 25 °C
Languages: en, fr, es, it, de, pt, zh, tr, hu, cz, pl, ro, hr, el, sl, sk, fi, ru, ja, ko
Manual Sampling: Initiates a sample collection independent of program in progress
Memory: Sample history: 4000 records;
Data log: 325,000 records;
Event log: 2000 records
Operating Mode: Continuous or non-continuous
Power Requirements (Hz): 50 - 60 Hz
Power requirements (Voltage): 230 V
Power supply: 230V
Probes included: No
Programs: Dual Programs: Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers
Program Stop Options: Multiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected)
Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container.
Pump flow rate: 4.8 L/min (1.25 gpm) at 1 m (3 ft) vertical lift with 3/8-in intake tube typical
Rain gauge input: No
Refrigeration Components and Plumbing: Corrosion protected with conformal all exposed copper tubing is insulated to avoid sweating and condensation
Sample Container: 1 - 2.5 Gallon
Sample Interval: Selectable in single increments from 1 to 9,999 flow pulses or 1 to 9,999 mins in one minute increments
Sample Pump: High-speed peristaltic, dual roller, with 0.95 ID x 1.6 OD cm (3/8 ID x 5/8-in. OD) pump tube
Sample Transport Velocity: 2.9 ft/s (0.9 m/s) with 15 ft (4.6 m) vertical lift, 16 ft of 3/8-in. vinyl intake tubing, 70°F (21°C) and 5000 ft elevation
Sample Trigger: When equipped with flow sensor or pH/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded
Sample Volume: Programmable in 10 mL increments from 10 - 10,000 mL
Sample Volume Accuracy: Typical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in. vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sample Volume Repeatability: Typical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sampling Mode: Pacing: Time Weighted, Flow Weighted, Time Table, Flow Table, Event
Distribution: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle
Sensor Ports: 2
Status Messages: Communicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature
Suction Hose Outer Diameter: 1/4" and 3/8" ID PTFE-lined Polyethylene with protective outer cover available in clear and black.
Temperature: Operating: 0 - 50 °C
Storage: -40 - 60 °C
Tubing: Pump tubing: 9.5 mm ID x 15.9 mm OD Silicone

Intake tubing: 1.0 - 4.75 m minimum length, 1/4" or 3/8" ID Vinyl or 3/8" ID PTFE-lined Polyethylene with protective outer cover (black or clear)
User Interface: Membrane switch keypad with 2 multiple function soft keys
User Interface Languages: Chinese, English, French, German, Italian, Spanish, Portuguese
Vertical Lift: Maximum of 28 ft using 29 ft of 3/8-in. vinyl intake tube at sea level at 20-25°C (68-77°F)
Weight: 63 kg
What's included?: 1 ea. AS950 controller with sensor ports on vinyl 230V refrigerated base
1 ea. Bottle kit (RF010030) includes 2.5 gallon polyethylene bottle w/cap (1918), extension tube (3527), composite tube support (8986) and full bottle shut-off (8847)
1 ea. 25' vinyl intake tubing (920)
1 ea. strainer (926)