Cable:
Polyurethane, 0.400 (±0.015) in. diameter; IP68 Standard length
9M (30 ft), maximum 305 m (1000 ft)
Cables are available in 2 styles:
–connectors both ends
–connector from sensor with open leads to desiccant hub,
desiccant hub with connector to logger.
Certifications:
FLO-DAR Sensor Model Numbers: 890004801, 890004901,
890004804, 890005201, 890004807, and 890005204
Frequency: 24.10GHz to 24.15GHz
Category: Field Disturbance Sensor
Output Field Strength: < 2.5 V/m (128dBuV/m) @ 3m, measured
per following standards
Certified to FCC Part 15.245: FCC ID: VIC-FLODAR24
Certified to Industry Canada Spec. RSS210. V7: IC No.:
6149A-FLODAR24
FLO-DAR Sensor Model Numbers: 890004802, 890004902,
890004805, 890005202, 890004808, and 890005205
Frequency: 24.16GHz to 24.19GHz
Category: Short Range Device Output Power (EIRP): < 10mW
(10dBm) @ 3m, measured per the following standard
Certified to ETSI EN 300 440-1 V1.6.1 (2010-08)
Compatible Instruments:
FL900
Dimensions :
160.5 W x 432.2 L x 297 D mm
(6.32 x 16.66 x 11.7 in.),
with SVS, D = 387 mm (15.2 in.)
Enclosure Construction:
IP68 Waterproof rating IP68
Waterproof rating, Polystyrene with
316 stainless steel bail tabs
Operating Temperature Range:
-10 to 50°C (14 to 122°F)
Power supply:
Supplied by FL900 Flow Logger,
FL1500 Flow Logger, or Flo-Logger
Range Selection:
Non Extended Range
Set-up/Data Retrieval:
FSDATA Desktop Data Management software is used for set-up,
data management, and report generation. It is compatible with
desktop/laptop computers utilizing Windows operating system.
Storage conditions:
-40 to 60°C (-40 to 140°F)
Surcharge Depth Method:
Piezo-resistive pressure transducer
with stainless steel diaphragm
Surcharge Depth Range:
3.5 m (138 in.), overpressure rating
2.5 x full scale
Surcharge Velocity Sensor Option:
Surcharge Velocity Sensor Included
SVS/IS option:
Surcharge Velocity Sensor, Intrinsically Safe Option
Warranty:
12 months
Weight:
4.8 kg (10.5 lbs.)
What's included?:
Flo-Dar AV Sensor with Surcharge Velocity Sensor, User manual