New: NH6000sc Ammonium Analyser, 2 channel, use 1 external sample filtration unit, with 1 sample pump for FX610, flow detect, 115 VAC

NH6000sc Ammonium Analyser, 2 channel, use 1 external sample filtration unit, with 1 sample pump for FX610, flow detect, 115 VAC
Product #: LXV461.99.04221
Unit Price Contact Hach
Ships within 3-5 weeks

Maximise uptime and accuracy with trusted technology

The NH6000sc ammonium analyser from Hach® uses fast, accurate and trusted GSE technology. The NH6000sc provides reliable measurements with automatic calibration, validation, and cleaning. A verification grab sample improves consistency between online and lab data through an automatic sampling process. Predictive diagnostics and supportive maintenance workflows help you maximise uptime.

Save time with biannual maintenance

The NH6000sc ammonium analyser reduced routine user maintenance frequency to only twice per year. Engineered with efficiency in mind, the instrument's streamlined design and optimised reagents make operation simple and user-friendly. With a standard cleaning cycle, the reagents have an extended replacement time of every 6-months.

Robust and lightweight intergrated filtration options

The integrated FX610 filtration system and the more rugged FX620 feature lightweight construction with improved air cleaning and innovative flow detection. These features ensure reliable functionality and reduced operational touchpoints. Plus, you’ll have the ability to remotely check that your sample is consistently supplied to your analyser to increase confidence in your results.

Specifications

Accuracy: With Standard Solution:
Measuring range 1: ≤ 1 mg/L: 3% of the measured value + 0.02 mg/L > 1 mg/L: 5% of the measured value + 0.02 mg/L
Measuring range 2: 3% of the measured value + 0.05 mg/L
Measuring range 3: 3% of the measured value + 1.0 mg/L
Measuring range 4: 4.5% of the measured value + 10 mg/L
Altitude: 2000 m maximum
Cable Length: Data and power cable: 2 m from edge of enclosure
Certifications: CE, UKCA, CMIM, FCC, ISED, certified to UL and CSA safety standards by TÜV
Controller Compatibility: Digital SC Controller. Controllers are sold separately.
Dimensions : 575 x 991 x 425 mm (22.63 x 39.01 x 16.73 in.)
Enclosure Rating: Rating: IP55, NEMA 3R UL50E
Material: PUR 66
Filtersystem included: Integrated sample supply pump for FX610 Filtration System
Indoor/Outdoor: Indoor or outdoor use
Lower Limit of Detection (LOD): Measuring range 1: 0.02 mg/L NH₄-N
Measuring range 2: 0.05 mg/L NH₄-N
Measuring range 3: 1 mg/L NH₄-N
Measuring range 4: 10 mg/L NH₄-N
Material: PUR 66 UV-resistant
Measurement method: Gas sensing electrode (GSE)
Measurement Range 2: 0.05 - 20 mg/L NH₄-N
Measurement Range 3: 1 - 100 mg/L NH₄-N
Measuring Interval: 5, 10, 15, 20 or 30 min. (user adjustable)
Measuring range: 10 - 1000 mg/L NH₄-N
Number of Channels: 2
Operating Temperature Range: -20 - 45 °C; 95% relative humidity, non-condensing
Options: Flow detection
Outputs: Relay, analog outputs, network interface through SC Controller
Parameter: Ammonium
Permissible Chloride Range: ≤ 1000 mg/L Cl-
pH Range: 5 - 9 pH
Pollution Degree: 2
Power supply: Power supplied by the SC controller. With the SC4500, an additional power box is needed.
Analyser and heated drain tubing (powered by analyser): 115 VAC or 230 VAC
Protection Class: Class 1
Range: 0.02 - 5.0 mg/L NH₄-N
Repeatability: With Standard Solution:
Measuring range 1: 3% of the measured value + 0.02 mg/L
Measuring range 2: 2% of the measured value + 0.05 mg/L
Measuring range 3: 2% of the measured value + 1.0 mg/L
Measuring range 4: 2% of the measured value + 10 mg/L
Response Time T90: Measuring range 1: ≤ 0.2 mg/L: 3 measurements required (15 total minutes minimum); > 0.2 mg/L: 1 measurement required (5 total minutes)
Measuring range 2: < 5 minutes
Measuring range 3: < 5 minutes
Measuring range 4: < 5 minutes
Sample Flow Rate: 1.0 - 20.0 L/h to the analyser from the external sample filtration
Sample Pressure: 2.5 bar (0.25 mPa) maximum
Sample Quality: Ultra filtrated or comparable (FX6x0 < 0.45 µm)
Sample Temperature: 4 - 40 °C
Special Remarks: The liquid level in the basin must be below the bottom of the analyser
Storage conditions: -20 - 60 °C; 95% relative humidity, non-condensing
Weight: Approximately 45 kg without chemicals