Single Parameter Monitoring Panel with SC4500 and CL17sc

Single Parameter Monitoring Panel with SC4500 and CL17sc
Product #: SPMP-CL
Unit Price Contact Hach
Ships within 3-5 weeks

Quality from start to finish​

Our panel configurations allows you to maximize the inherent quality of the instruments, providing peace of mind while leveraging Hach’s 100 years of water quality innovations.

Up and running in no time

Our preassembled, ready-to-use solutions streamline the process between purchasing and startup.

Ease of installation

When you buy a water quality monitoring station from Hach, you’ll receive an expertly designed, preassembled panel that makes installation straightforward and user friendly.

What's included?

CL17sc Chlorine Analyzer with Pressure Regulator Installation Kit (8572400)
SC4500 Controller, Claros-enabled, 5x mA Output, 2 digital Sensors, 100-240 VAC, US plug (LXV525.99EA1551)

Specifications

Accuracy: ± 5% or ± 0.04 mg/L (whichever is greater) from 0 - 5 mg/L Cl₂
± 10% from 5 - 10 mg/L Cl₂
Air purge: Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar maximum
Alerts: Low and high chlorine. Dirty cell. Low and high sample flow.
Certifications: CE compliant with: EN 61326-1, CISPR 11, EN 50581
ACMA RCM
South Korea KC Certificate
North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003
Controller: SC4500
Cycle Time: 2.5 minutes
Dimensions (H x W x D): 711 mm x 330 mm x 218 mm
Drain: ½-inch ID flexible hose
Enclosure Rating: IP66
Inlet: ¼-inch OD polyethylene tube, quick-disconnect fitting
Inlet Pressure: 0.3 - 5.2 bar supplied to Y-strainer
0.1 - 0.3 bar supplied to analyser
Installation Kit: Panel Mounted
Interferences: Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃.
Light source: LED, measurement at 510 nm, 1 cm light pathlength
Lower Limit of Detection (LOD): 0.03 mg/L
Mounting: Panel - wall or rack mount
Operating Humidity: 0 - 90% relative humidity, non-condensing
Operating Temperature Range: 5 - 40 °C
Parameter: Chlorine, free; Chlorine, total residual
Power requirements (Voltage): 100-240 VAC ±10%, 50/60 Hz; 1 A
Process connection: Sample drain: ½" NPT or hose barb
Range: 0.03 - 10 mg/L Cl₂
Reagent Consumption: 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days
Sample Flow Rate: 60 - 200 mL/min through the instrument
Sample Inlet Connection: ¼" OD tubing
Sample Pressure: 4.5 - 75 psi
Sample Requirements: Y-strainer filtration with 40-mesh screen or higher
Sample Temperature: 5 - 40 °C (41 - 104 °F)
Sensor to Controller Distance (Maximal): 1000 m (3280 ft), per RS485
Sensor Type: Digital output
Solution Type: Drinking water, raw and treated
Weight: 9 kg / 20 lbs
What's included?: CL17sc Chlorine Analyzer with Pressure Regulator Installation Kit (8572400)
SC4500 Controller, Claros-enabled, 5x mA Output, 2 digital Sensors, 100-240 VAC, US plug (LXV525.99EA1551)