TSS TITANIUM7 sc TriClamp, Suspended Solids TriClamp inline Sensor without a Wiper

TSS TITANIUM7 sc TriClamp, Suspended Solids TriClamp inline Sensor without a Wiper
Product #: LXV330.99.20001
Unit Price Contact Hach

Twelve different instrument versions and thirty mounting styles

The only titanium suspended solids probe in the market designed for the most difficult environments

High temperature probe that withstands temperatures of up to 90ºC

Specially designed probes for measurement in high hygienic regulatory conditions

TSS sc has a unique compensation system to overcome the effects of air bubbles

What's included?

Turbidity & Suspended Solids sensor, user manual

Specifications

Accuracy: Turbidity up to 1000 NTU: < 5 % of measurement value or ± 0.01 NTU, whichever is greater
NTU: 5 % of measured value or ± 0.01 NTU, whichever is greater
Ambient Temperature: 0 - 60 °C (briefly 80 °C)
Application: Titanium7 Corrosive Environments
Automatic Wiper: No
Cable Length: 10 m (optional extension cables available)
  10 m (optional extension cables available)
Calibration: Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Calibration Method: Turbidity: Formazin or Stablcal Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids: Sample specific, based on gravimetric analysis with a correction factor procedure.
Controller Compatibility: SC200, SC1000, SC4500. All controllers sold separately
Diameter: 40 mm
Flow: Max. 3 m/s (the presence of air bubbles affects the measurement)
Installation style: User Defined, with TriClamp
Length: Inline sensor (TriClamp): 332 mm
Maintenance Interval: 1 h/month
Material: Gasket: FKM; Wiper: PA (GF), TPV
Max Temperature: 60 °C
Measurement method: Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 60 nm
Solids (TS): 90º and 120º scattered light measurement, wavelength = 60 nm
Model: TSS Titanium7 sc
Mounting Configurations: TriClamp
Operating Temperature Range: 0 - 60 °C
Parameter: Turbidity, Suspended Solids
Pressure Range: 10 bar or 100 m
Range: Turbidity (TRB): 0.001 - 9999 NTU
Solids (TSS): 0.001 - 500 g/L
Repeatability: TSS content: < 4 %
Turbidity: < 3 %
Response Time T90: 1 - 300 s adjustable
Special Notes: Installation note:
Distance sensor–wall
> 50 cm (Turbidity)
> 10 cm (TSS)
Warranty: 12 months
Weight: approx. 1.6 kg
What's included?: Turbidity & Suspended Solids sensor, user manual