Accuracy:
                                            
                                            
                                        
									    ± 5% or ± 0.01 mg/L (whichever is greater) from 0 - 4 mg/L; ± 10% from 4 - 5 mg/L
                                    
                                
    						
								
                                    
                                        
                                            
                                                Air purge:
                                            
                                            
                                        
									    Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar maximum
                                    
                                
    						
								
                                    
                                        
                                            
                                                Alerts:
                                            
                                            
                                        
									    Low and high chlorine. Dirty cell. Low and high sample flow.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Certifications:
                                            
                                            
                                        
									    CE compliant with: EN 61326-1, CISPR 11, EN 50581
ACMA RCM
South Korea KC Certificate
North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003
                                    
                                
    						
								
                                    
                                        
                                            
                                                Controller Compatibility:
                                            
                                            
                                        
									    SC200, SC1000, SC4500. All controllers sold separately
                                    
                                
    						
								
                                    
                                        
                                            
                                                Cycle Time:
                                            
                                            
                                        
									    2.5 minutes
                                    
                                
    						
								
                                    
                                        
                                            
                                                Dimensions (H x W x D):
                                            
                                            
                                        
									    342 mm x 329 mm x 177 mm
                                    
                                
    						
								
                                    
                                        
                                            
                                                Drain:
                                            
                                            
                                        
									    ½-inch ID flexible hose
                                    
                                
    						
								
                                    
                                        
                                            
                                                Enclosure Rating:
                                            
                                            
                                        
									    IP66
                                    
                                
    						
								
                                    
                                        
                                            
                                                Inlet:
                                            
                                            
                                        
									    ¼-inch OD polyethylene tube, quick-disconnect fitting
                                    
                                
    						
								
                                    
                                        
                                            
                                                Inlet Pressure:
                                            
                                            
                                        
									    0.3 - 5.2 bar supplied to Y-strainer
0.1 - 0.3 bar supplied to analyser
                                    
                                
    						
								
                                    
                                        
                                            
                                                Installation Kit:
                                            
                                            
                                        
									    Standpipe Installation Kit <10 psi sample pressure
                                    
                                
    						
								
                                    
                                        
                                            
                                                Interferences:
                                            
                                            
                                        
									    Other oxidising agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃.
                                    
                                
    						
								
                                    
                                        
                                            
                                                Light source:
                                            
                                            
                                        
									    LED, measurement at 510 nm, 1 cm light pathlength
                                    
                                
    						
								
                                    
                                        
                                            
                                                Lower Limit of Detection (LOD):
                                            
                                            
                                        
									    0.008 mg/L Cl₂ at 25 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Mounting:
                                            
                                            
                                        
									    Wall mount
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating Humidity:
                                            
                                            
                                        
									    0 - 90% relative humidity, non-condensing
                                    
                                
    						
								
                                    
                                        
                                            
                                                Operating Temperature Range:
                                            
                                            
                                        
									    5 - 40 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Parameter:
                                            
                                            
                                        
									    Chlorine, total residual (ULR)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Power requirements (Voltage):
                                            
                                            
                                        
									    12 VDC, 400 mA maximum (supplied by the controller)
                                    
                                
    						
								
                                    
                                        
                                            
                                                Range:
                                            
                                            
                                        
									    0.008 - 5 mg/L Cl₂
                                    
                                
    						
								
                                    
                                        
                                            
                                                Reagent Consumption:
                                            
                                            
                                        
									    0.5 L of buffer solution and 0.5 L of indicator solution in 31 days
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Flow Rate:
                                            
                                            
                                        
									    60 - 200 mL/min through the instrument
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Requirements:
                                            
                                            
                                        
									    Y-strainer filtration with 40-mesh screen or higher
                                    
                                
    						
								
                                    
                                        
                                            
                                                Sample Temperature:
                                            
                                            
                                        
									    5 - 40 °C
                                    
                                
    						
								
                                    
                                        
                                            
                                                Warranty:
                                            
                                            
                                        
									    12 months
                                    
                                
    						
								
                                    
                                        
                                            
                                                Weight:
                                            
                                            
                                        
									    4.1 kg
                                    
                                
    						
								
                                    
                                        
                                            
                                                What's included?:
                                            
                                            
                                        
									    ULR CL17sc Chlorine Analyser, Standpipe Installation Kit, and User Manual. User provides screws and/or anchors for mounting.