TIM845 pH/EP/IP Routine Potentiometric Titrator, Biburette motor positions without Burette stand (Radiometer Analytical)

OBSOLETE ITEM

TIM845 pH/EP/IP Routine Potentiometric Titrator, Biburette motor positions without Burette stand (Radiometer Analytical)
Product #: R41T039

OBSOLETE ITEM

Intelligent design ensures effortless setup and maintenance

Electrodes and tubing slot secure in place with one easy movement thanks to our unique bayonet concept. For convenient installation and maintenance, the mono-block titrating burette is mounted in no time.

Intuitive interface guides you at every step

Titration Manager prompts you with clear-text messages in a choice of languages, making it so much easier when you're doing routine work. The titration curve is easy to follow live on the large graphic display together with electrode and titrant status.

One-touch selections and preprogrammed functions make titrations easy to run

Interface gives instant access to routine functions, making it by far the simplest titrator of its generation. Preset routines guide you when running analyses, repeating measurements and performing maintenance. Titrator allows you to automatically sequence and repeat measurements, ideal for direct measurement followed by a titration. Predefined electrode and reagent libraries mean you save time and effort setting up your application.

High-resolution burette, unique addition technique and special algorithms ensure accurate results

Integrated titrating burettes offer the highest resolution on the market giving unbeatable accuracy for your potentiometric titrations. Innovative electronic design supporting effective PID regulation loop algorithms combined with incremental or dynamic continuous titrant addition modes allow you to reach end points or to determine inflection points even more quickly. Whether you are working with sharp or weak curves or running single or multiple IP, detection is fast and reliable.

Assistant function and extensive data storage give complete confidence in your results

On the Titrator, all interfaces are standard so you can add to your system as you wish. Increase your sample throughput from 10 to 126 samples using one of our sample changers. Add up to 4 additional burettes and 4 electrode inputs thanks to the versatile ABU52 dual burette system. Simplify data entry by connecting a standard PC keyboard and a bar code reader. Obtain virtually unlimited storage capacity for your results with TitraMaster 85 PC Software.

What's included?

TIM845,NB Potentiometric Titration Workstation consists of the TIM845 Potentiometric Titration Manager biburette with a full set of connecting cables, cell accessories. Electrode & Burette stand B5xx to be ordered separately.

Specifications

Analogue Electrodes Input (High Impedance) : 2 HiZ
Automatic Reagent Addition(s): 1 prior titration starts
Balance: Serial RS232
Beaker Volumes Accepted: 5 to 400 mL
Burette: Stand / Tap Type: Fixed
Burette: Volumes Available: 1 ml, 5 ml, 10 ml, 25 ml & 50 ml
Burette Max Permissible Errors: Random and Systematic: Both Comply with ISO8655-3…..Random Error: ± 0.05 - 0.1 % ……Systematic Error: ± 0.2 - 0.6 %
Burette Motor Resolution: 18000 steps
Calibration Interval: 1 to 999 days
Compliance Certifications: CE marking
cETLus certification
Continuous Dynamic Titrant Addition : Addition speed from 0.01 to 50 mL/min
Diameter: (excl. tubing)
Dimensions (H x W x D): 380 mm x 230 mm x 457 mm
Display Type: Graphic 128x128 dot LCD protected from spillages with PMP cover
Embedded Titrating / Dosing Unit(s): 2 embedded burette motors
End Point Titration: 1 to 2 end points
Incremental Dynamic Titrant Addition: Incremental dose from 0.01 to 10 mL with record on stable reading or max time
Incremental Monotonic Titrant Addition: Incremental dose from 0.01 to 10 mL with record on stable reading or max time
Inflection Point Titration: 1 to 4 Equivalent points
Internal Calibration Storage Capacity: Last 1 FIFO management
Internal Data Storage: Last 60 FIFO management
Internal Method Storage Capacity: 10
IP Rating: Fully splashproof chemical resistant lathene
Languages: English, German, Danish, French, Italian, Spanish, Swedish
Length: 450 mm
Method Coupling / Sequencing: Up to 2 methods linked in the same beaker
Method Coupling / Sequencing 2: to
Method ID: Up to 16 characters, aphanumeric
mV Direct Measurement: -2000 - +2000 mV with record on stable reading or max time
mV Resolution: 0.1 mV
Non-Volatile Memory: Battery saved
Number of user programmable methods: 10
Operating Humidity: 20 - 80 %
Operating Interface: Rubber soft touch alphanumeric keypad.
Operating Temperature: 5 - 40 °C
Password Protection: Up to 10 characters, aphanumeric
PC Data Transfer Software: Serial RS232 TitraMaster 85
pH Direct Measurement: -9 to 23 pH with record on stable reading or max time
pH Electrode calibration: 1 - 5 Standards, with auto recognition & acceptance criteria
pH Resolution: 0.01 pH
Polarised electrode input: -1 - +1 mA in 1 µA step, DC or AC
Power Requirements (Hz): 47.5 - 63 Hz
Power requirements (Voltage): 115/220 V AC
Printer: Serial RS232
Result ID: Up to 16 characters, aphanumeric
Sample Changer: Serial RS232 with SAC850
Sample Changer Stack: up to 25 samples
Sample ID: Up to 16 characters, aphanumeric
Sample Results: up to 4 results per analysis
Sample Stand: Embedded with Magnetic stirring
Specific Technology: pH/EP/Stat
Stirring Speed: 0 to 1100 rpm in 50 rpm steps
Temperature Resolution: 0.1 °C
TTL Input / Output: 1 Input/1 Ouput 0-5V
Type: pH-Stat
User Defined Sample Result Calculations: 1 equation per analysis
User ID: Up to 16 characters, aphanumeric
User Programs: 7 preset: Alkalinty, TAN, Acidity in Juice, SO2 in wine, Chlorides, OH- in Cu bath.
Weight: 5 kg excluding reagent bottles.
What's included?: TIM845,NB Potentiometric Titration Workstation consists of the TIM845 Potentiometric Titration Manager biburette with a full set of connecting cables, cell accessories. Electrode & Burette stand B5xx to be ordered separately.